STUDENT CYPRES 2

For Student Skydivers

The Student CYPRES has unique activation parameters that better accommodate the safety needs of a student during the initial learning progression.

If the descent rate is approximately the same rate as freefall, the unit will activate at approximately 750 ft (default setting, same as the Expert), but if the descent rate is lower than freefall speed and still above 29mph (e.g. with partially opened canopy), the unit will activate at approximately 1000 ft (300m) AGL (default setting).

Unlike the Expert and Tandem models, it is recommended that the Student unit be turned off in the event that the jump is aborted as the vertical descent rate of the aircraft is still fast enough to activate the unit.
Cable length of control unit: approx. 1000 mm
Volume: approx. 144 cm³
Weight: approx. 214 grams
Activation altitude: approx. 1000/750-130 feet (approx. 300/225 – 40 meter)
Activation speed: approx. >29 mph (13 m/s)
Length, width, height of the processing unit: approx. 85 x 43 x 32 mm
Length, width, height of the control unit: approx. 65 x 18 x 6.5 mm
Length, diameter of the release unit: approx. 43 x 8 mm
Cable length of the release unit (including release unit): approx. 500 mm
Storage temperature: +71° to -25° Celsius
Storage pressure: 200 to 1094 hPa ( 5.906 to 32.306 In.Hg)
Working temperature: +63° to -20° Celsius*
Maximum allowable humidity: up to 99.9 % rel. humidity
Waterproof: up to 24 hours down to a depth of 8 feet (2.5 meters)
Dropzone offset adjustment limits: ±3000 feet or ±1000 m
Operating range below / above sea level: -2140 feet to +26,000 feet (-650 m to +8000 m)
Functioning period: 14 hours from switch-on
Power supply: service life warranty**
Maintenance: For units with DOM 12/15 and earlier the maintenance is mandatory to be performed 4 and 8 years after the original DOM.
For units made in 2016 the maintenance is recommended to be performed 4 and 8 years after original DOM.
For units with DOM 01/17 and later the maintenance is recommended to be performed 5 and 10 years after the original DOM.***
Warranty Period: see Airtec warranty policy
Service life: DOM prior 01.01.2017: 12.5 years from date of manufacture
DOM later 01.01.2017: 15.5 years from date of manufacture

*These temperature limits do not mean the outside (ambient) temperatures but rather temperatures inside the processing unit. Therefore, these limits won‘t have any meaning until the processing unit itself has reached the temperatures in question. In actual fact, these limits will rarely be reached due to the location of the CYPRES in the reserve container, and the insulating properties of the processing unit pouch and parachute canopies.** If recommended maintenances have been performed within the scheduled time frames.

*** According to the present knowledge base.

Airtec article numbers for the several configurations of the standard Student CYPRES 2. Meter scale or feet scale are factory preset as ordered, you can change the scale of your unit on your own anytime. Converting for the use from a 1-pin to a 2-pin container or vice versa only requires the in field swap of the appropriate cutter type (1-pin or 2-pin cutter).

  • Student feet 1-pin: 3221100
  • Student feet 2-pin: 3222100
  • Student meter 1-pin: 3211100
  • Student meter 2-pin: 3212100

Documents

hh

PILOT INFORMATION

The pilot information sheet includes all necessary information for dropzone pilots on the DZ on one sheet.

Click here

hh

QUICK GUIDE HANDLING CYPRES 2

A rough guide for handling the push button of the CYPRES 2 for the following actions:

switching on (switching off)

access to unit information

Dropzone Offset (setting for another landing elevation)

raising activation altitude

changing the scale meter feet

changing the mode (C-MODE unit only)

Click here

hh

CYPRES 2 USER GUIDE – ENGLISH

The CYPRES 2 user’s guide provides thorough information for all handling aspects of the CYPRES 2. In addition you’ll find helpful information for your daily skydive and the AAD side of life.

Click here